Please use this identifier to cite or link to this item: https://dair.nps.edu/handle/123456789/5166
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDouglas H. Nelson, Kyle S. Edwards-
dc.contributor.authorJustin Lee, Roberto M. Garcia-
dc.contributor.authorJim Johnson, Steven West-
dc.contributor.authorBryan L. Kelchner-
dc.date.accessioned2024-06-03T16:29:13Z-
dc.date.available2024-06-03T16:29:13Z-
dc.date.issued2024-05-01-
dc.identifier.citationAPAen_US
dc.identifier.urihttps://dair.nps.edu/handle/123456789/5166-
dc.descriptionSYM Paperen_US
dc.description.abstractAs the Department of Defense (DoD) and industry continue to advance the development of high energy laser (HEL)–based directed energy weapon (DEW) systems, the need for modernized test and evaluation (T&E) and experimentation capabilities for DEW has become critical. This will allow airborne, ship-based, and land-based HEL systems to be tested against air and surface targets in a well-understood atmospheric environment. T&E capabilities in maritime test arenas and land environments will be enhanced by instrumenting open-air test ranges with advanced sensor systems, including atmospheric optical turbulence measurement systems, which play a critical role in HEL device beam and fire control. Teknicare, Inc., in conjunction with NAWC WD Pt Mugu, has conducted extensive improvement and testing of reverse engineered differential temperature sensors at various locations including San Nicolas Island and Point Mugu NAWC on the PMSR as well as China Lake NAWC. This effort has included research of related designs, schematics, theses, and reports conducted at Naval Postgraduate School by Dr. Donald L. Walters and his students. The devices, now known as Walters Probes, make use of precision fine wire thermocouples separated at a known distance, including an added variable separation capability, to provide a measurement of temperature difference. The associated electronics provide necessary amplification and sampling rate to ensure a measurable ensemble average is obtained to determine CT2 at the Walters Probe location. These systems are capable of low noise operation and hence measurement of CT2 values that render atmospheric optical turbulence at extreme values indicative of terrestrial neutral vents, therefore they can easily measure values expected in the near maritime environment. Testing and evaluation have been conducted to determine reliability, sustainability, operability, and maintainability revisions to be undertaken to ensure the Walters Probes meet DEW T&E mission OPTEMPO requirements.en_US
dc.description.sponsorshipARPen_US
dc.language.isoen_USen_US
dc.publisherAcquisition Research Programen_US
dc.relation.ispartofseriesAcquisition Management;SYM-AM-24-112-
dc.subjectAtmospheric Optical Turbulenceen_US
dc.subjectDirected Energyen_US
dc.subjectHigh Energy Laseren_US
dc.subjectLaser Test and Evaluationen_US
dc.subjectLaser Performance Modeling and Simulationen_US
dc.titleTest and Evaluation of Revised Concept Walters Probes—High Sensitivity Differential Temperature, CT2, Probes for Atmospheric Optical Turbulence Characterizationen_US
dc.typeTechnical Reporten_US
Appears in Collections:Annual Acquisition Research Symposium Proceedings & Presentations

Files in This Item:
File Description SizeFormat 
SYM-AM-24-112.pdf477.8 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.